WIKA 威卡

气体处理设备

精确的测量数据提升建筑性能

全球最终能源需求中约有40 %左右用于建筑。许多公共建筑和商业建筑中的空调与通风系统并没有调整到最佳调节,包含过时的部件或尺寸太大,导致高达50 %的能源成本。

为了节能,现代建筑几乎都密封的严严实实。空气质量的恶化将危害人们的福祉和工作表现。长此以往,甚至会导致健康问题。

精确的测量数据为空调与通风系统的能源和成本效益控制奠定了基础,并以此保障健康的室内气候与住户满意度。

威卡的智能传感产品组合确保了持续、精确的压力、温度、湿度和空气质量记录。模拟和数字信号传输以及LoRa®广域网无线电解决方案能够顺畅地集成到任何自动化和控制系统以及云环境中。因此,您也可以通过改造解决方案让现有系统适应未来需求。


气体处理设备 × Δp

Pressure control

Pressure control
T

Frost protection

Frost protection
T

Flow reversion of ERS based of temperature difference (ΔT) or enthalpy difference (Δh) between ETA and ODA

Flow reversion of ERS based of temperature difference (ΔT) or enthalpy difference (Δh) between ETA and ODA
RH

Humidity control

Humidity control
VOC

Demand based air quality control

Demand based air quality control
Δp

Air flow rate control

Air flow rate control
Δp

Filter monitoring

Filter monitoring
RH

Frost protection/freezing point calculation with EHA temperature

Frost protection/freezing point calculation with EHA temperature
Δp

Frost protection

Frost protection
CO₂

Demand based air quality control

Demand based air quality control
T

Exhaust air temperature control

Exhaust air temperature control
CO₂

Demand based air quality control

Demand based air quality control
T

Frost protection startup control; Temperature control with outdoor air temperature compensation

Frost protection startup control; Temperature control with outdoor air temperature compensation
T

Temperature control

Temperature control
RH

Humidity control

Humidity control
T

Water-side temperature control

Water-side temperature control
T

Air-side frost protection

Air-side frost protection
T

Water-side temperature control

Water-side temperature control
T

Water-side temperature control

Water-side temperature control
Δp

Air flow rate control

Air flow rate control
Δp

Filter monitoring

Filter monitoring
Δp

Air leakage control of ERS

Air leakage control of ERS
Δp

Pressure control

Pressure control
T

Frost protection startup control; Temperature control with outdoor air temperature compensation

Frost protection startup control; Temperature control with outdoor air temperature compensation
Δp

Filter monitoring

Filter monitoring
T

Minimum limit of supply air temperature; Supply air temperature control

Minimum limit of supply air temperature; Supply air temperature control
RH

Flow reversion of HRS based of temperature difference (ΔT) or enthalpy difference (Δh) between ETA and ODA

Flow reversion of HRS based of temperature difference (ΔT) or enthalpy difference (Δh) between ETA and ODA
气体处理设备
最小化选择

以下27个产品与您的选择相对应。您仍未找到产品?请联系我们